simpleware logo  
 
Home Software Services Applications Corporate News
  Contact     FAQ    Sitemap     
  Applications      
   
bullet Industrial
bullet Materials
bullet Medical
bullet Natural Sciences
bullet Case Studies

Particle Tracking through the Human Respiratory System

T. Collins, G. Tabor
University of Exeter, School of Engineering, Computer Science and Mathematics, Exeter, UK.

Notable Features of Model

  • Based on in vivo patient data
  • CFD analysis

Purpose of the Study

The study of airflow through the human respiratory system is a complex problem, which has in the past necessitated the use of numerical models based on grossly simplified geometry. The aims of the study were (a) to compare an idealized geometry with that of a physiologically realistic geometry and (b) to examine the flow of air and track the trajectories of water vapour particles, through the human respiratory system.

Mesh Mesh in +ScanFE   idealised geometry CFD idealized geometry   real geometry CFD from MRI scan

Scanning and segmentation in ScanIP

In vivo MRI scans were performed at a resolution of 1.44 x 1.44 x 1.44 mm.

ScanIP was used to create a physiologically realistic model of the human respiratory system from the MRI data. In order to create a 3D representation of just the airways, first they had to be defined against their surroundings. In ScanIP a combination of Threshold and FloodFill tools were used to create a mask of the airways based on the grey scale values of the image.

Mesh Generation in +ScanFE

In +ScanFE the first operation was to define the contact surfaces of each part that was intended for export. In the case of the human airways, three contact surface needed to be created:
(1) contact from the airways to the background which would become the walls of the airways,
(2) contact from the airways to the exterior which would become the inlet and outlet of the airways, and
(3) contact between the airways and themselves.

Once the contact surfaces were defined, the mesh was created within +ScanFE and exported in Fluent format.

CFD Analysis in Fluent

In Fluent, calculations were performed using a turbulent flow rate of 0.0012 m3 s-1 under both aspiratory and expiratory flow conditions. There was very little agreement between the flow structures of the idealised geometry and that obtained from the MRI scan data. Re-circulatory regions in the idealised geometry were induced by sharp edges in the geometry but none of these re-circulatory flows were found to exist in the MRI geometry. It was evident that the curved features of the MRI geometry helped keep the flow attached to the walls thus preventing separation, re-circulation and adverse pressure gradients.

A tracking study of a range of water vapour particles with a median diameter of 5.0 µm and a 90th percentile diameter of 10.0 µm, showed that small variations in particle diameter had little effect over the eventual destinations of the particles whereas the zones of the respiratory system with the most complex and curving geometry, trapped a higher percentage of larger diameter particles. These findings agree with those found previously in relation to vapour distribution from medical nebulizers.

 

  top of page
  © 2000 - 2008 by Simpleware Ltd. All Rights Reserved
Innovation Centre - Rennes Drive - Exeter EX4 4RN - United Kingdom
Email: info@simpleware.com Web: www.simpleware.com